一、新型柴油发电机使用手册

1、新的柴油发电机在初始运行的50小时内,建议将负载控制在额定功率的80%以下,并严格遵循制造商的磨合要求,以优化发动机的长期可靠性和运行效率。

2、用于工程机械的柴油发电机,在最初的50小时内应在部分负载(建议额定功率的50%~80%)下运行,避免长时间怠速或突加负载,以确保发动机良好磨合。

3、根据规范要求进行日常维护保养,使用新设备后需检查油压表、温度表、警示灯及其他仪器,确保其正常运作。

4、未添加润滑油的油底壳需要按照规定添加润滑剂;如果冷却系统已经充满冷却液,则必须检查冷却剂的性能,如不符合要求,应将其放掉,并重新添加符合标准的冷却剂。

1,For the first 50 hours of operation, the new diesel generator should be operated at no more than 80% of its rated load capacity.2,For diesel generators used in construction machinery, they should operate at partial load (recommended 50%~80% of rated power) during the first 50 hours of operation. Prolonged idling or sudden load increases should be avoided to ensure proper engine break-in.

3,according to the standard requirements for daily maintenance, after the use of new equipment need to check the oil pressure gauge, temperature gauge, warning light and other instruments to ensure its normal operation.4,the oil pan without lubricating oil needs to add lubricant in accordance with the regulations;If the cooling system is already filled with coolant, the performance of the coolant must be checked, and if it does not meet the requirements, it should be discharged and the coolant that meets the standard should be added again.